TEST
RESULTS
EZ-4719





COPY
UNITED STATES TESTING COMPANY, INC.
HOBOKEN, NJ
NUMBER
67323
REPORT
March 25, 1960

Subject:

Two (2) samples of adhesives, sampled and identified by Client, for tensile shear tests before and after oxygen aging.


Test Procedure:
Two panels of each type of adhesive were prepared and tested in accordance withe the procedure outlined in Military Specification MIL-A-5090B, amendment 1, dated 15 March, 1955. One panel of each type adhesive was tested at room temperature and one panel of each type adhesive was tested after 3 days oxygen aging.

Tensile Shear Strength, psi.

Room Temperature
Oxygen Aged
Specimen
EC 800
4719
EC 800
4719
1
5.7
10.0
19.8
50.2
2
4.6
16.6
22.0
51.3
3
3.5
6.7
21.5
46.3
4
4.2
5.7
22.0
31.4
5
2.5
5.9
17.7
49.1
Average
4.1
9.0
20.6
45.7


PRECISION ADHESIVES, INC.
51 Washington St., PO Box 910, Perth Amboy, NJ 08861
Phone: 800-456-3021
Fax: 732-442-9568

Click here to return to HVAC product list.